4. MECHANICAL SYSTEM
4-40
COPYRIGHT © 2001 CANON INC. CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
G. Delivery/Reversing
Assembly
1. Removing the Delivery/Reversing
Assembly
1)
Open the front cover (left), and remove the left
cover.
2)
Slide out the fixing unit.
3)
Loosen the two screws [1].
Figure 4-301G
4)
Remove the four screws [2], and open the
external and internal delivery units; then,
disconnect the two connectors [3], and pull out
the delivery/reversing assembly [4] to the left
side.
Figure 4-302G
2. Removing the Fixing Separation
Claw
1)
Open the front cover (left), and slide out the
fixing unit; then, open the external and internal
delivery units.
2)
Remove the screw [1], and remove the
delivery sensor assembly [2].
[1]
[2]
[2]
[3]
[4]
[1]
[2]
[5]
[3]
[4]
Figure 4-303G
3)
Remove the screw [3], and remove the
positioning pin [4] of the separation claw unit,
and remove the separation claw unit [5].
Figure 4-304G