COPYRIGHT © 2001 CANON INC. CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
4-29
4. MECHANICAL SYSTEM
4)
Remove the E-ring [5] (resin), and remove the
pick-up roller [6] from the rear.
5)
Remove the E-ring [7] (resin).
Figure 4-306B
6)
Pull out the feeding roller from the shaft [9]
together with the belt pick-up roller shaft [8].
Figure 4-307B
4. Removing the Pick-Up Assembly
Separation Roller
1)
Remove the pick-up assembly.
2)
Remove the screw [2], and remove the lower
guide [1].
[5]
[6]
[7]
[8]
[9]
1. When removing the pick-up
roller shaft or the like, take extra
care not to damage the sensors
found around the part.
2. When installing the feeding roller
[1] to the pick-up assembly, in
stall it so that the gear [2] of the
feeding roller is toward the rear
of the machine.
[1]
[2]
(front of machine)
Figure 4-308B
Figure 4-309B
[1]
[2]
Summary of Contents for Vizcam 1000