3. OPERATION AND TIMING
COPYRIGHT © 2001 CANON INC. CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
3-30
B. Sequence of Basic Operations (original exposure system)
1. Sequence of Operations
• Without Pre-Scanning (with original detection OFF, ACS OFF, APS OFF)
• With Pre-Scanning (1 scan over original; standard mode)
• With Pre-Scanning (2 scans over original; standard mode + marking)
[A]
Shading correction.
[B]
Original position detection, black original detection, AE measurement.
[C]
Original scanning.
[D]
Marking area scanning.
Figure 3-203
Scanning lamp
Original scanner motor (M29)
Original scanner home position sensor (PS37)
Start key ON
CNTR
[C]
[A]
Scanning lamp
Original scanner motor (M29)
Original scanner home position sensor (PS37)
Start key ON
CNTR
[A]
[B]
[C]
Scanning lamp
Original scanner motor (M29)
Original scanner HP sensor (PS37)
Start key ON
CNTR
Standard CW rotation.
High-speed rotation.
Reversal (scanner in reverse).
[A]
[B]
[D]
[C]