4. MECHANICAL SYSTEM
E. SALT Sensor
1. Removing the SALT Sensor
1)
Open the front cover, and lift the hopper
assembly all the way up.
2)
Disconnect the two connectors [1], and
remove the screw [2]; then, pull out the SALT
sensor unit [3].
Figure 4-901E
2. Cleaning the SALT Sensor Unit
1)
Remove the SALT sensor unit.
2)
Spread paper, and remove the toner which
has collected on the No. 2 scoop-up sheet [1].
•
When holding the SALT sensor
unit, take care not to touch its
stainless steel area [4] (where
black plastic film is attached; fail
ure to do so could damage the
shutter assembly).
Figure 4-902E
•
If you have replaced the SALT
sensor, be sure to replace the
developing agent of the corre
sponding color. (See the instruc-
tions on how to replace.)
3)
Dry wipe the No. 2 scoop-up sheet with lint-
free paper or clean it with a blower brush.
Exercise care not to subject the po-
sitioning pin at the rear of the SALT
sensor unit to impact to avoid defor-
mation.
Take care not to deform the No. 2
scoop-up sheet.
4)
Spread paper, and pour out the toner which
has collected on the plastic film [2] over the
paper.
Figure 4-903E
[2]
[3]
[1]
[4]
[1]
[2]
Summary of Contents for Vizcam 1000
Page 12: ......
Page 30: ......
Page 44: ......
Page 86: ......
Page 254: ......
Page 372: ......
Page 374: ......
Page 418: ......
Page 438: ......
Page 442: ......
Page 754: ......
Page 764: ......
Page 766: ......
Page 840: ...0501GR PRINTED IN JAPAN IMPRIME AU JAPON This publication is printed on 100 reprocessed paper...