7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
[7]
[8]
Figure 7-222
10) Using two screws [9], fit the metal fixing [10] of
the scanner cable to the No. 1 mirror mount
through the angular hole in the side plate.
[9]
[10]
Figure 7-223
[9]
[10]
Figure 7-224
11) Remove the mirror positioning tool.
REF.
You need not adjust the cable ten-
sion.
1. Check to make sure that the scan-
ner cable is not twisted or has not
ridden over the pulley.
2. Move the No. 1 mirror mount and
the No. 2 mirror mount by hand to
make sure that they move
smoothly; at this time, take care
not to touch the reflecting plate.