COPYRIGHT © 2001 CANON INC. CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
4-69
4. MECHANICAL SYSTEM
7. Removing the Dust-Proofing Glass
1)
Lift the hopper assembly (See chapter 4. VII.
HOPPER SYSTEM, A-1. Removing the
Hopper Assembly).
2)
Slide the dust-proofing mirror [1] in the
direction of the arrow to pull it out to the front.
8. Removing the BD Unit
•
C/Bk BD Unit
1)
Remove the primary high-voltage transformer
unit.
2)
Remove the lamp regulator.
3)
Remove the four mounting screws [1], and
disconnect the five connectors [2]; then,
remove the fan mount [3].
Figure 4-619B
When installing the dust-proofing
glass [1], insert it by forcing it in the
direction of arrow A; then, push it
down in the direction of arrow B to
set.
Figure 4-620B
Figure 4-621B
4)
Remove the screw [4], and remove the rear
unit cover [5].
Figure 4-622B
[1]
[1]
A
B
[1]
[2]
[2]
[1]
[1]
[3]
[4]
[5]