5. INSTALLATION
5-8
COPYRIGHT © 2001 CANON INC. CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
Step
5
6
7
8
9
Work
Perform the same steps for the M, C,
and Bk toners as for the Y toner.
Open the right cover, and remove the
hopper assembly right cover and the
left cover (1 screw each).
Remove the two fixing screws from the
hopper assembly.
Holding both left and right grips, pull the
hopper assembly to the front and then
lift it. (It will be locked when lifted to the
topmost position.)
• Shift down the lever of the transfer
unit, and release the transfer belt from
the photosensitive drum.
• Slide out the transfer unit, and remove
the transfer unit cover (2 mounting
screws).
• Put the transfer unit back into its
original position. (Keep the releasing
lever released.)
Remarks
Do not dispose of the toner
bottle in fire; it may tear open
or explode.
Left cover
Screw
Right cover
Screw
Fixing screws
Check to make sure that the
hopper assembly is se-
curely locked in position by
the naked eye.
Grip
Grip
Lever
Transfer unit
Summary of Contents for Vizcam 1000
Page 12: ......
Page 30: ......
Page 44: ......
Page 86: ......
Page 254: ......
Page 372: ......
Page 374: ......
Page 418: ......
Page 438: ......
Page 442: ......
Page 754: ......
Page 764: ......
Page 766: ......
Page 840: ...0501GR PRINTED IN JAPAN IMPRIME AU JAPON This publication is printed on 100 reprocessed paper...