4. MECHANICAL SYSTEM
4-86
COPYRIGHT © 2001 CANON INC. CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
2)
Put lubricant on the lint-free paper, and apply it
along the edge of the blade in a thin, even film.
Points to Note
If the lubricant is not even, the copies may
carry white, vertical lines.
• Limit the application to the edge of the
blade, i.e., where it will come into contact
with the drum.
• Do not rub the edge with force. Tap lightly
over the edge to avoid damage.
• For the edge, apply it in three strokes in the
direction of the arrow (same direction)
4. Removing the Cleaner Side Seal
1)
Remove the developing assembly/cleaning
unit from the copier (See chapter 4. IX.
PROCESS UNIT SYSTEM, A-2. Removing
the Developing Assembly/Cleaning Unit).
2)
Remove the screw [1], and remove the
cleaner side seal [2].
Figure 4-905B
Figure 4-906B
Points to Note When Installing
the Cleaner Side Seal
• Be sure that the gap between the blade and
the cleaner side seal is 0.5 mm as shown.
Try pressing on the cleaner side seal to
make sure that it will not get caught on the
blade.
Figure 4-907B
[2]
[1]
[1]
[2]
0~0.5mm
0~0.5mm