COPYRIGHT © 2001 CANON INC. CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
4-103
4. MECHANICAL SYSTEM
8)
Remove the two screws [8] and two bushings
[9]; then, remove the web [10].
Figure 4-1004B
2. Installing the Upper Fixing Web
When installing the web [1], install the length
detecting lever [2] as shown in Figure 4-1005B.
Figure 4-1005B
C. Fixing Lower Cleaning
Assembly
1. Removing the Lower Fixing Web/
Lower Fixing Blade
1)
Open the front cover (left), shift down the
fixing lever, and slide out the fixing unit.
2)
Remove the fixing assembly knob (1 screw),
and remove the fixing lever (2 screws).
3)
Remove the two screws, and remove the
fixing assembly front cover.
4)
Open the external delivery unit and the
internal delivery unit.
5)
Remove the two fixing screws [1], and pull out
the lower fixing web unit [2].
Figure 4-1001C
[8]
[9]
[10]
[1]
[2]
[1]
[1]
[2]