6-6
Status Diagnostic Messages
Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
A0011 Starting lockout active
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
As an option, certain digital drive controllers can be equipped with a drive
interlock. The drive interlock prevents the unintended start of a servo axis.
This is realized by separating the electronic control system of the power
output stage from the power output stage by means of a relay contact.
When the drive interlock is active the control panel of the drive reads
"AS".
See also Project Planning Manual Control Section, keyword "Drive
interlock"
A0011 - Attributes
Display:
AS
Mess. no.:
A0011 (hex)
A0012 Control and power sections ready for operation
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
Supported by Supply Unit:
HMV01
The
A0012 Control and power sections ready for operation
diagnostic
message signals that the drive is provided with control voltage and the
power has been switched on. The drive is ready for power output.
Note:
This status is displayed on the control panel of the drive with
"Ab" ("
A
ntrieb
b
ereit" = Drive ready).
The diagnostic message
A0012 Control and power sections ready for
operation
signals that the supply unit is ready for switching in the mains
contactor.
Note:
This status is displayed on the control panel of the device with
"Bb" ("
b
etriebs
b
ereit" = ready for operation).
A0012 - Attributes
Display:
Ab
Mess. no.:
A0012 (hex)
For HMS, HMD, HCS
For HMV