Rexroth IndraDrive
Command Diagnostic Messages
9-59
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
C0243 Brake check function not possible
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
In the
P-0-0525, Holding brake control word
parameter the automatic
brake check was selected/activated. When initializing the function an
error occurred.
Cause
Remedy
Holding brake is not controlled
Activate control of holding brake in
P-0-0525, Holding
brake control word
P-0-0540, Torque of motor holding brake
is 0
Parameterize
P-0-0540, Torque of motor holding
brake
correctly by means of data sheet for brake or
motor
For removing command errors see "Command Errors"
C0243 - Attributes
Display:
C0243
Mess. no.:
C0243 (hex)
C0244 Act. modulo value cycle greater than max. travel range
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the execution of the command
S-0-0128, C0200 Communication
phase 4 transition check
an error was detected.
Cause
Remedy
Calculated modulo value for actual value cycle is
greater than value parameterized in
S-0-0278,
Maximum travel range
Check parameterization of
S-0-0278, Maximum travel
range
and if necessary adjust it to modulo value for
actual value cycle
–
or
–
Check parameterization of modulo value for actual value
cycle and adjust it to
S-0-0278, Maximum travel range
For removing command errors see "Command Errors"
C0244 - Attributes
Display:
C0244
Mess. no.:
C0244 (hex)
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01