6-36
Status Diagnostic Messages
Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
A0512 Test run active
Supported by Supply Unit:
HMV01
The mains contactor has been switched in. DC bus voltage is available.
All monitoring thresholds have been adjusted for a test run at 43 V mains
voltage.
Note:
This operating status is only available for manufacturer-side
testing and developing purposes!
A0512 - Attributes
Display:
lb
Mess. no.:
A0512 (hex)
A0520 DC bus quick discharge active
Supported by Supply Unit:
HMV01
The braking resistor is presently short-circuiting the DC bus in order to
reduce the DC bus voltage as quickly as possible.
Note:
The "DC bus short circuit" function (ZKS) was activated via the
terminal strip X32 at the HMV.
A0520 - Attributes
Display:
ZKS
Mess. no.:
A0520 (hex)
A0800 Unknown operating mode
Supported by Supply Unit:
HMV01
There isn
’
t any diagnostic message existing for the activated operating
mode.
A0800 - Attributes
Display:
AF
Mess. no.:
A0800 (hex)