9-98
Command Diagnostic Messages
Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
C2001 Command not enabled
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The execution of the "Release motor holding brake" command (C2000)
was aborted by an error.
Cause:
The command can only be executed if it is allowed by bit 5 in the
P-0-0525, Holding brake control word
parameter.
Remedy:
Set bit 5 in parameter P-0-0525 to "allowed".
See also Functional Description "Motor Holding Brake"
C2001 - Attributes
Display:
C2001
Mess. no.:
C2001 (hex)
C2101 Brake check only possible with drive enable
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
It is impossible to execute the "Brake check" command (C2100).
Cause:
The
P-0-0541, C2100 Brake check command
was activated but drive
enable ("AF") had not been set.
Remedy:
Switch drive to "AF" ("
A
ntriebs
f
reigabe" = drive enable), then start the
C2100 command.
See also Functional Description "Motor Holding Brake"
C2101 - Attributes
Display:
C2101
Mess. no.:
C2101 (hex)
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01