![Bosch REXROTH IndraDrive Troubleshooting Manual Download Page 81](http://html.mh-extra.com/html/bosch/rexroth-indradrive/rexroth-indradrive_troubleshooting-manual_40580081.webp)
6-24
Status Diagnostic Messages
Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
A0132 Cam shaft, lagless, encoder 1, virt. master axis
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The drive is in the cam shaft mode. The function has been derived from
the principle of the mechanical cam shaft. There is a fixed position
relation between master axis and slave axis. The position command
values are taken from a table that is accessed by means of the master
axis position.
The drive follows the command value without any lag error.
Encoder 1 means that the position encoder is mounted to the motor shaft
(indirect measuring of the axis position). Virtual master axis means that
the master axis position is calculated by the control unit.
See also Functional Description "Electronic Cam Shaft with Real/Virtual
Master Axis"
A0132 - Attributes
Display:
AF
Mess. no.:
A0132 (hex)
A0133 Cam shaft, lagless, encoder 2, virt. master axis
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The drive is in the cam shaft mode. The function has been derived from
the principle of the mechanical cam shaft. There is a fixed position
relation between master axis and slave axis. The position command
values are taken from a table that is accessed by means of the master
axis position.
The drive follows the command value without any lag error.
Encoder 2 means that the position encoder is mounted to the machine
axis (direct measuring of the axis position). Virtual master axis means that
the master axis position is calculated by the control unit.
See also Functional Description "Electronic Cam Shaft with Real/Virtual
Master Axis"
A0133 - Attributes
Display:
AF
Mess. no.:
A0133 (hex)
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01