9-118
Command Diagnostic Messages
Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
C3504 Measuring encoder not available
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the execution of the command
P-0-0340, C3500 Command
Determine encoder correction values
an error was detected.
Cause
Remedy
Measuring encoder does not supply any signal or is
not recognized by controller
Check whether signals of measuring encoder are
reaching controller. If necessary, replace encoder or
encoder cable
Measuring encoder not available, not connected or
not registered
Connect measuring encoder and register it in
P-0-0076,
Encoder type 3 (measuring encoder)
C3504 - Attributes
Display:
C3504
Mess. no.:
C3504 (hex)
C3505 No encoder selected
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the execution of the command
P-0-0340, C3500 Command
Determine encoder correction values
an error was detected.
Cause
Remedy
At start of command
P-0-0340, C3500 Command
Determine encoder correction values
there hadn
’
t
any encoder been selected in
P-0-0341, Control
word for encoder correction
Select encoder in
P-0-0341, Control word for encoder
correction
C3505 - Attributes
Display:
C3505
Mess. no.:
C3505 (hex)