F7010 Safety related limited increment exceeded
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The drive is shut down with velocity command value reset.
The drive automatically switches to safety related standstill and the output
stage is switched off via two channels.
As soon as the axis has stopped the safety door can be opened.
Cause:
In safety function "special mode motion", position range defined in
parameter
•
P-0-3243, Safety related limited increment 1
or
•
P-0-3253, Safety related limited increment 2
or
•
P-0-3263, Safety related limited increment 3
or
•
P-0-3273, Safety related limited increment 4
has been exceeded.
Remedy:
Start command
S-0-0099, C0500 Reset class 1 diagnostics
in order to
clear error and then set drive enable again.