XX:ERASE
Brief Description:
Clearing active
The loader (
FL:ERASE
= firmware loader,
LD:ERASE
= loader in control
section) is in the clearing mode. The requested memory range / module is
being cleared.
XX: PROG
Brief Description:
Programming active
The loader (
FL:PROG
= firmware loader,
LD:PROG
= loader in control
section) is in the programming mode. The transmitted data are written to
the requested address in the memory range / module.
XX: CKS
Brief Description:
Checksum calculation active
The checksum calculation is active. Subsequent to the calculation a
comparison with the stored checksums is run.
Note:
"
FL: CKS
" means firmware loader and "
LD: CKS
" means
loader in control section.
XX:E ADR
Brief Description:
Warning: address error
Cause
Remedy
Address read from IBF file is outside of allowed
range
Please contact our service department
Note:
"
FL:E ADR
" means firmware loader and "
LD:E ADR
" means
loader in control section.
XX:E SEC
Brief Description:
Warning: range error
Cause
Remedy
Data in IBF concerning memory range (firmware,
loader, boot kernel) are incorrect
Please contact our service department
Note:
"
FL: SEC
" means firmware loader and "
LD: SEC
" means
loader in control section.