![Bosch REXROTH IndraDrive Troubleshooting Manual Download Page 128](http://html.mh-extra.com/html/bosch/rexroth-indradrive/rexroth-indradrive_troubleshooting-manual_40580128.webp)
Rexroth IndraDrive
Error Messages
7-33
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
F7014 Acceleration threshold exceeded
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The drive is shut down with velocity command value reset.
The drive automatically switches to safety related standstill and the output
stage is switched off via two channels.
As soon as the axis has stopped the safety door can be opened.
Cause:
In safety function "special mode motion", threshold parameterized in
parameter
•
P-0-3245, Safety related deceleration/acceleration ramp 1
or
•
P-0-3255, Safety related deceleration/acceleration ramp 2
or
•
P-0-3265, Safety related deceleration/acceleration ramp 3
or
•
P-0-3275, Safety related deceleration/acceleration ramp 4
has been exceeded.
Remedy:
Start command
S-0-0099, C0500 Reset class 1 diagnostics
in order to
clear error and then set drive enable again.
F7014 - Attributes
Display:
F7014
Mess. no.:
F7014 (hex)
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01