Rexroth IndraDrive
Command Diagnostic Messages
9-107
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
C2803 Measured values at zero point and max. value identical
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the execution of the command
P-0-0220, C2800 Analog input
adjust command
an error was detected. The execution of the command
was aborted.
Cause
Remedy
During zero point and gain adjust, the same
voltage value was provided at analog input
Voltage provided at input has to be modified between
two steps of adjust (voltage value for zero adjust: 0 V,
voltage value for gain adjust: maximum input voltage)
See also Functional Description "Analog Inputs"
C2803 - Attributes
Display:
C2803
Mess. no.:
C2803 (hex)
C2804 Automatic adjust failed
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The command
P-0-0220, C2800 Analog input adjust command
was
aborted due to an unspecified error. Please contact our service
department.
C2804 - Attributes
Display:
C2804
Mess. no.:
C2804 (hex)