Rexroth IndraDrive
Command Diagnostic Messages
9-87
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
C1217 Setting only possible in
’
Ab
’
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the execution of the command for commutation offset
determination (C1200) an error was detected.
Cause
Remedy
The drive was not ready at the start of the command,
the display did not read "Ab"
1. Switch drive to communication phase 4, if there isn
’
t
any error present the display reads "bb"
("
b
etriebs
b
ereit" = ready for operation)
2. Switch power on, drive goes to operating mode, the
display reads "Ab" ("
A
ntrieb
b
ereit" = drive ready)
3. Now start command C1200
C1217 - Attributes
Display:
C1217
Mess. no.:
C1217 (hex)