F2032 Plausibility error during commutation fine adjust
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
When a synchronous motor with incremental measuring system is
homed, the value of
P-0-0521, Effective commutation offset
is
converted to the home point reference and compared to the optimized
commutation offset in
P-0-0508, Commutation offset
. If the deviation
determined due to this comparison is too great, the error F2032 is
generated and the drive is shut down.
Note:
If the deviation is too great, the operational safety of the motor
is no longer guaranteed because a "runaway effect" of the
motor can occur.
Cause
Remedy
Initial commissioning was not or incompletely carried
out
Carry out initial commissioning
Motor encoder was replaced
Carry out initial commissioning
Motor connections (U, V, W) were mixed up
Check and if necessary correct motor connection
Values in
P-0-0508, Commutation offset
and/or
P-0-3008, Commutation offset, encoder memory
were manipulated
Check value stored in
P-0-0508, Commutation offset
;
carry out initial commissioning again, if required
See also Functional Description "Establishing the Position Data
Reference (Drive-Controlled Homing)"