C0799 An invalid index was set
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
At the time the command
S-0-0262, C07_x Load defaults procedure
command
was started no valid value had been entered in
P-0-4090,
Index for C07 Load defaults procedure
.
Note:
The function of the command
S-0-0262, C07_x Load defaults
procedure command
can be set via
P-0-4090, Index for C07
Load defaults procedure
.
After the command was cleared the value in
P-0-4090, Index
for C07 Load defaults procedure
is automatically set to "0"
again.
C0799 - Attributes
Display:
C0799
Mess. no.:
C0799 (hex)
C0851 Parameter default value incorrect (-> S-0-0021)
Supported by Supply Unit:
HMV01
Note:
This command error can only occur as a result of the
C0800
Load basic parameters command
that can only be used by
the manufacturer!
C0851 - Attributes
Display:
C0851
Mess. no.:
C0851 (hex)