Rexroth IndraDrive
Command Diagnostic Messages
9-121
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
C3903 Command execution impossible
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
It was impossible to start the command "abrasion of brake" (
P-0-0544,
C3900 Command Abrasion of brake
).
Cause
Remedy
Brake control has not been activated in parameter
P-0-0525, Holding brake control word
Activate brake control in parameter
P-0-0525, Holding
brake control word
Value in
P-0-0540, Torque of motor holding brake
is 0
Enter correct value for
P-0-0540, Torque of motor
holding brake
See also Functional Description "Motor Holding Brake"
C3903 - Attributes
Display:
C3903
Mess. no.:
C3903 (hex)
C4001 Error during safety related homing procedure
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The command
P-0-3228, C4000 Homing procedure command
channel 2
was not or incorrectly executed.
Cause
Remedy
There hasn
’
t been any home switch configured
Configure a home switch in
P-0-3211, Safety
technology I/O control word, channel 2
Maximum allowed deviation of actual position
values 1 and 2 was exceeded during command
execution
Check parameterization of
P-0-3229, Tolerance
window for safety related homing procedure
; comply
with parameterized tolerance window during command
execution
Note:
If necessary, reset the module (switch control voltage off and
then on again) in addition to trouble shooting.
C4001 - Attributes
Display:
C4001
Mess. no.:
C4001 (hex)
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01