7-80
Error Messages
Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
F2009 - Attributes
Display:
PL
Mess. no.:
F2009 (hex)
F2010 Error when initializing digital inputs/outputs
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
An error occurred during the first initialization of the drive (initialization of
digital inputs/outputs).
Cause
Remedy
Conflict with last stored parameters of digital
inputs/outputs
Check following parameter contents and correct them, if
necessary:
-
P-0-0300, Digital I/Os, assignment list
- P-0-0301, Digital I/Os, bit numbers
- P-0-0302, Digital I/Os, direction
F2010 - Attributes
Display:
F2010
Mess. no.:
F2010 (hex)
F2011 PLC - Error nr. 1
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
In conjunction with technology functions the PLC integrated in the drive
(optional expansion package "drive PLC") allows the user generating error
messages (F2011...F2014) within the PLC program.
The causes of the error are depending on the respective PLC project (or
the active technology function). If the error message is generated by a
technology function made available by Bosch Rexroth, the causes and
remedies are contained in the description of the technology function.
See also documentation "Rexroth IndraMotion MLD-S"
F2011 - Attributes
Display:
F2011
Mess. no.:
F2011 (hex)