C2903 Error when accessing the MMC
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the execution of
P-0-4072, C2900 Command Firmware update
from MMC
a check is run to find out whether the firmware was correctly
loaded.
Cause
Remedy
A transmission error occurred during transmission
of firmware from MMC
Execute
P-0-4072, C2900 Command Firmware update
from MMC
again.
If error occurs again, contact a Rexroth service engineer
Firmware file (ibf file) available on MMC is not
correct (does not match control section)
Use different MMC with firmware file appropriate for
control section
–
control section CSH01.1C: firmware MPH
–
control section CSB01.1x: firmware MPB
–
control section CDB01.1x: firmware MPD
Note:
If the command error occurs during the transmission of the
firmware to an optional module, the respective system error
(F8xxx) is displayed in addition to the command error C2903.
C2903 - Attributes
Display:
C2903
Mess. no.:
C2903 (hex)
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01