![Bosch REXROTH IndraDrive Troubleshooting Manual Download Page 380](http://html.mh-extra.com/html/bosch/rexroth-indradrive/rexroth-indradrive_troubleshooting-manual_40580380.webp)
Rexroth IndraDrive
Command Diagnostic Messages
9-109
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
C2904 Error when accessing the flash
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the execution of the
P-0-4072, C2900 Command Firmware
update from MMC
an error occurred.
Cause
Remedy
Due to voltage fluctuations in device an active
request was aborted
Execute
P-0-4072, C2900 Command Firmware update
from MMC
again
Control section is defective
Replace control section or entire drive controller
Note:
Only Rexroth service engineers or especially trained users are
allowed to replace the control section. The replacement of the
entire drive controller is described in the Project Planning
Manual for the power section.
Note:
If the command error occurs during the transmission of the
firmware to an optional module, the respective system error
(F8xxx) is displayed in addition to the command error C2904.
C2904 - Attributes
Display:
C2904
Mess. no.:
C2904 (hex)
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01