F8203 - Attributes
Display:
F8203
Mess. no.:
F8203 (hex)
F8806 Timeout during loading process
Supported by Supply Unit:
HMV01
During the loading of the DC bus before switching on the power supply
("soft start") the expected DC bus voltage could not be reached within a
time window.
Cause
Remedy
Too many additional capacitances were connected
Reduce number of additional capacitance modules
There is short circuit or load of low impedance in DC
bus
Check wiring of DC bus connection
F8806 - Attributes
Display:
F8806
Mess. no.:
F8806 (hex)
F8813 Connection error mains choke
Supported by Supply Unit:
HMV01
After the power supply had been switched on a wiring error of the mains
choke (e.g. incorrect phase sequence of the mains phases) was detected.
Cause
Remedy
Mains choke was incorrectly connected
Check and correct connection of mains choke
F8813 - Attributes
Display:
F8813
Mess. no.:
F8813 (hex)