Installing the Hardware
Installation and Operation
29
4.
Wait while the library performs its power-on self-test. During this
time, the following activities occur:
S
The cooling fan begins to rotate.
S
The LCD illuminates and displays the Main Screen.
S
The tape drives perform their power-on self-tests.
S
The library performs its power-on self-test.
Tape drive power-on self-test
During its power-on self-test, each tape drive checks its operating
conditions and sends status information to the library.
Library power-on self-test
During its power-on self-test, the library:
S
Engages the locking solenoid in the door
S
Moves the CHM to the home positions on the short and long axes
S
Moves the drum to the home position
S
Retracts the entry/exit port transport arm
S
Verifies the CHM's full range of motion by moving it to the top of
the long axis
S
Touches each cartridge to update the cartridge inventory
S
Moves to the home position on the long axis
The power-on self-test takes from 2½ to 5 minutes, depending on the
number of cartridge magazines present.
Summary of Contents for Scalar AIT 440
Page 1: ...INSTALLATION AND OPERATING GUIDE SCALAR AIT 440 480...
Page 2: ...Scalar AIT 440 480 Libraries Installation and Operation...
Page 7: ...vi Scalar AIT 440 480 Notes...
Page 11: ...x Scalar AIT 440 480 Notes...
Page 25: ...xxiv Scalar AIT 440 480 Notes...
Page 101: ...Operating the Tape Drives Installation and Operation 77 Notes...
Page 135: ...Chapter 8 112 Scalar AIT 440 480 Notes...
Page 153: ...Chapter 9 130 Scalar AIT 440 480 Notes...
Page 179: ...Chapter 11 156 Scalar AIT 440 480 Notes...
Page 185: ...Appendix A 162 Scalar AIT 440 480 Notes...