Chapter 9
118
Scalar AIT 440/480
To run the Park test, press
>
@
or
>
@
from the Diagnostics Menu to select
Park and press
>(QWHU@
. The library moves the CHM to the bottom of the
long axis.
Move Cartridge
The Move Cartridge test picks a cartridge from one element and moves
it to another.
³
Important
If you insert a cartridge in a tape drive,
the tape drive will not automatically eject the cartridge.
To run the Move Cartridge test:
1.
From the Diagnostics Menu, press
>
@
or
>
@
to select Move Cartridge
and press
>(QWHU@
. The library displays the following screen:
2.
Press
>
@
and
>
@
to select the element index (shown in the upper
right corner) of the cartridge slot from which you want the CHM to
pick the cartridge.
S e
t
S o u r
c e
0
↑
I
n c
r e a s e
↓
D e c
r e a s e