Operating the Tape Drives
Installation and Operation
71
1.
Make sure security is disabled (see
page 39
).
2.
Change to LCD Interface control mode (see
page 53
).
3.
From the Main Menu, press
>
@
to select Maintenance Menu and
press
>(QWHU@
.
4.
From the Maintenance Menu, press
>
@
to select Clean Drives Menu
and press
>(QWHU@
.
5.
Use
>
@
to select the tape drive you want to clean as described below,
and press
>(QWHU@
.
S
Clean Drive 1 (top tape drive)
S
Clean Drive 2 (second from top)
S
Clean Drive 3 (third from top)
S
Clean Drive 4 (bottom tape drive)
The CHM picks the cleaning cartridge from the fixed cartridge slot
and inserts it in the tape drive you specified. The tape drive
automatically performs the cleaning process and ejects the cartridge
when the process is complete (several minutes). When the tape drive
ejects the cartridge, the CHM picks the cartridge from the tape drive
and replaces it in the fixed cartridge slot.
6.
Confirm that the cleaning was done by looking at the LEDs on the
front of the tape drive. The Tape and Status LEDs should not be
falshing Mode 2. If the LEDs are still flashing Mode 2, replace the
cleaning cartridge and clean the tape drive again. If the LEDs are
still flashing Mode 2 after the second cleaning, there may be a
problem with the tape drive.
Summary of Contents for Scalar AIT 440
Page 1: ...INSTALLATION AND OPERATING GUIDE SCALAR AIT 440 480...
Page 2: ...Scalar AIT 440 480 Libraries Installation and Operation...
Page 7: ...vi Scalar AIT 440 480 Notes...
Page 11: ...x Scalar AIT 440 480 Notes...
Page 25: ...xxiv Scalar AIT 440 480 Notes...
Page 101: ...Operating the Tape Drives Installation and Operation 77 Notes...
Page 135: ...Chapter 8 112 Scalar AIT 440 480 Notes...
Page 153: ...Chapter 9 130 Scalar AIT 440 480 Notes...
Page 179: ...Chapter 11 156 Scalar AIT 440 480 Notes...
Page 185: ...Appendix A 162 Scalar AIT 440 480 Notes...