DC Puse Power Supply
【
DC-10-4P
】
8
APPENDIX
84
READ Command
The following commands are for reading various parameters and the power status from DC.
Table 8-5: READ command list
Command
Transmission data
Acknowledgment data
Command
Command name
Capacity
Data content
Capacity
Data content
0x82
Name?
1byte
0x00 -> Master
0x01 -> Slave 1
:
0x06
-> Slave 6
7byte
The inquired model name of the power supply
unit is replied as follows.
DC-10-4P
:
0x01
0x83
Power Units
Numbers?
1byte
Replies the setup of number of power supply
units connected in M/S manner.
The maximum total number of units is six.
The second byte of the 2-byte data to be
responded is the number of 10-4P units.
10-4P is five: 0x0500
0x84
All Units Power?
2byte
The maximum output value is replied (electric
power).
The maximum value varies according to the
number of units connected.
10kW
->100
10kW×6
台
60kW -> 600
0x87
FAIL UNIT NUM
1byte
If an ERROR is occurred with an power supply
unit connected in M/S manner, the unit
generating the ERROR is replied with this
command. The bit corresponding to the unit
stands up. If an ERROR is occurred in multiple
units, all the corresponding bits stand up.
MASTER
:
0x01(00000001)
SLAVE1
:
0x02(00000010)
SLAVE2
:
0x04(00000100)
SLAVE3
:
0x08(00001000)
SLAVE4
:
0x10(00010000)
SLAVE5
:
0x20(00100000)
0x90
ON STATUS?
1byte
This sends back the power status. The status
can be judged from the following bits.
0x01 = ON/OFF
0x02 = READY
0x04 = OUTPUT
0x08 = SETPOINT
0x10 = INTLK
0x20 = RESERVED
0x40 = WARN
0x80 = FAIL
Содержание DC-10-4P