DC Puse Power Supply
【
DC-10-4P
】
8
APPENDIX
80
Command
Transmission data
Acknowledgment data
Command
Command name
Capacity
Description
Capacity Description
0x16
IGNITION
VOLTAGE
2byte
Set the ignition voltage of the power supply.
It can be set in the range from 800V to 1,500V in steps of 10V.
1byte
STATUS
0x18
Master Reset
Reset ERROR occurring in the power supply.
1byte
STATUS
0x1C
RAMP MODE
1byte
0x00 : DISABLE
0x01 : ENABLE
1byte
STATUS
0x1D
RAMP TIME
2byte
This is the setting of the rise time from START to the set value
(Level).
This can be set in the range of 0.05 to 600 seconds.
5(0.05 second)
:
0x0005.
60000(600 second)
:
0xEA60
1byte
STATUS
0x1E
RAMP START
1byte
This is the starting value (Level) for starting Ramp operation.
This is set by the percentage with respect to Level.
0
~
100%
100
:
0x64
1byte
STATUS
0x20
POWER LIMIT
2byte
The limit of the output power can be set.
The limit value depends on the composition of the connected
power supplies.
0
~
60.0
kW →
600
600
:
0x0258
1byte
STATUS
0x21
VOLTAGE LIMIT
2byte
The limit of the output voltage can be set.
The limit value depends on the power supply model.
0
~
800V
800
:
0x0320
1byte
STATUS
0x22
CURRENT LIMIT
2byte
The limit of the output current can be set.
The limit value depends on the composition of the connected
power supplies.
A value 10-hold larger than the desired set value.
0
~
15
0.0A →
1500
1500
:
0x05DC
1byte
STATUS
0x24
PULSE
PARAM SELECT
1byte
Two types of parameters (SET_A, SET_B) related to ARC
and pulse oscillation shown below can be set.
If each parameter is changed, the data is stored in the active
SET.
This command switches between SET_A <-> SET_B.
SET_A
:
0x00
SET_B
:
0x01
The parameter that can be switched:
・
0 x25 DCMD ARC SHUT DOWN TIME
・
0x2B
ARC SHUT DOWN VOLTAGE
・
0x2C
ARC SHUT DOWN CURRENT
・
0x42
PULS CYCLE
・
0x43
PULS WDTH
・
0x45
PARC_OSON
(1ST
、
2ND
、
ENBL)
・
0x46
PULS HARD ARCJGE
・
0x48
PULS HARD JDGE COUNT
・
0x49
PULS HARD SHUT DOWN TIME
1byte
STATUS