DC Puse Power Supply
【
DC-10-4P
】
8
APPENDIX
81
Command
Transmission data
Acknowledgment data
Command
Command name
Capacity
Description
Capacity Description
0x25
DCMD ARC SHUT
DOWN TIME
1 byte
It is a setting of shutdown time for ARC processing in DC
mode setting. Following values (fixed) can be selected for the
shutdown time.
0x01=1000us
0x0C=20000us
0x02=2000us
0x0D=25000us
0x03=3000us
0x0E=30000us
0x04=4000us
0x0F=35000us
0x05=5000us
0x10=40000us
0x06=6000us
0x11=45000us
0x07=7000us
0x12=50000us
0x08=8000us
0x09=9000us
0x0A=10000us
0x0B=15000us
1byte
STATUS
0x2B
ARC SHUTDOWN
VOLTAGE
2byte
This is the setting of an ARC detection level by voltage.
The minimum settable changing step is 10 (V).
0,40
~
500V
500
:
0x01F4
1byte
STATUS
0x2C
ARC SHUTDOWN
CURRENT
1byte
This is the setting of an ARC detection level by current.
The minimum settable changing step is 10 (A).
0
~
90A
90
:
0x005A
1byte
STATUS
0x2D
Counter Reset
This is the reset command of the ARC counter.
1byte
STATUS
0x40
PULS_MODE
1byte
This is the command for selecting a pulse oscillation mode.
Continuous mode: 0x00
One pulse mode : 0x01
DC mode:
0x02
1byte
STATUS
0x41
PULS_OSC
1byte
This is set for synchronized operation using optical
synchronization cables.
No synchronization (CINT):
0x00
System with synchronization 1 (CMST): 0x01
System with synchronization 2 (CMST): 0x02
If a system with synchronization is selected, it is necessary to
set PULSE LINK SET (0x47).
With no settings, ERROR is raised.
1byte
STATUS
0x42
PULS_CYCL
2byte
This is the command for setting oscillating frequency in the
continuous mode.
The minimum unit can be set in the range from 5kHz to 250
kHz.
Depending on the frequency range, the unit that can be set
varies.
5kHz to 150 kHz: In the unit of 1 (kHz)
150kHz to 250 kHz: In the unit of 5 (kHz)
250
:
0x00FA
1byte
STATUS
0x43
PULS_WDTH
2byte
This is the command for setting the inversion pulse width of
the output.
The minimum settable changing step is 0.1 (μs).
It can be set in the range from 0.4.μs to 5.0μs.
The value in which the value intended to set is multiplied by
10 is transmitted.
0.4 → 4
:
0x0004
5.0 → 50
:
0x0032
However, the upper limit for setting is limited depending on
the currently registered value of PULS_CYCL(0x42).
1byte
STATUS