DC Pulse Power Supply
【
DC-10-4P
】
5
HOW TO OPERATE
52
CONT: Inter-pulse ARC generating times for shifting into HARD ARC processing can be
changed.
If the inter-pulse ARC is generated for the number of times specified during JDGE TIME, it
shifts into the HARD ARC.
DCMD: The parameter for ARC processing in DCMD can be changed.
SHDN: The output shutdown time for the ARC processing can be changed.
SHDN: The output shutdown time for the ARC processing in DCMD can be changed.
SHDN: The output shutdown time for the ARC processing can be changed.
It can choose from 1000/2000/3000/4000/5000/6000/7000/8000/9000/10000/15000/20000/
25000/30000/35000/40000/45000/50000usec.
LEVL: The electric voltage and current level for detecting the ARC can be changed.
VLEV: The electric voltage level for detecting the ARC can be changed.
ILEV: The electric current level for detecting the ARC can be changed.
VLEV: The electric voltage level for detecting the ARC can be changed.
0V and from 40 to 500V can be specified. The value can be selected in the unit of 10V.
If “0V” is specified, the ARC detection by means of electric voltage is not carried out.
ILEV: The electric current level for detecting the ARC can be changed.
From 0 to 90A can be specified. The value can be selected in the unit of 1A.
MODE: Two types of oscillating frequency (SET A or SET B), inversion pulse width, and ARC
parameters, prearranged according to the usage, can be switched over.
OTHR
:
this enables one to select ON/OFF of the ignition voltage and various options.
IG V: this enables one to change the ignition voltage.
SETP: this enables one to change the judgment criterion of SETPOINT.
HOST: this enables one to change the settings in the SERIAL communication mode.
IG V
:
this enables one to change the ignition voltage.
The selectable range is 800 to 1,500V in steps of 10V.