DC Pulse Power Supply
【
DC-10-4P
】
4
DESCRIPTION OF FUNCTIONS
29
4-4. About each monitor signal and LEVEL signal in system configuration
The rated voltage value against each monitor signal (VOUT, IOUT, POUT) and LEVEL signal varies
depending on the power system configuration. See the table below.
Table 4-7: System power correspondence table at power setting (VOUT, IOUT, POUT)
Number of 10-4P
units in use: α
Output voltage:
monitor signal;
VOUT 0 to 10V
0
~
1500V
Output current:
monitor signal;
IOUT 0 to 10V
0
~
(
α
×25)A
EX.
:
10kW: 2 units 0
~
(2×25)A
⇒
0
~
50A
Output voltage:
monitor signal;
POUT 0 to 10V
0
~
(α×10)kW
EX
:
10kW
:
2 units 0
~
(2×10)kW
⇒
0
~
20kW
Table 4-8: System power correspondence table at power setting (LEVEL)
Number of 10-4P
units in use: α
Output voltage
setting level:
LEVEL 0 to
10V
In V-control
0
~
1500V
※
In I-control
0
~
(α×25)A
Ex.
:
10kW
:
2 units 0
~
(2×25)A
⇒
0A
~
50A
In P-control
0
~
(α×10)kW
Ex.
:
10kW
:
2 units 0
~
(2×10)kW
⇒
0kW
~
20kW
* In the USER control and the SERIAL communication control
Use the LEVEL signals as: 10.0 Vmax for P control; 10.0 Vmax for I control; 5.34 Vmax for V control (5kHz to 150
kHz); and 4.34 Vmax for V control (155kHz to 250 kHz).
When surpassing the above level, the output is restricted in the rated power, and if the level is further increased,
the output is stopped by ERROR.
4-5. About DC output sequence
The output sequence is as follows.
INTERLOCK
DC ON
t 時間
READY
DC OFF
DC 出力
H
L
H
L
H
L
H
L
OFF
ON
FAIL
H
L
30 ~ 50ms
20 ~40ms
0.5~1ms
20 ~40ms
0.5~1ms
40 ~50ms
0.5~1ms
20 ~40ms
0.02ms
Figure 4-3: DC output sequence
DC output
Time: t