DC Puse Power Supply
【
DC-10-4P
】
8
APPENDIX
88
Command
Transmission data
Acknowledgment data
Command
Command name
Capacity
Data content
Capacity
Data content
0xB5
PARC OSON?
6byte
The parameter on the specified PARC is
replied. The following parameters are
collectively replied.
○
PARC_
1
ST_TIME
"PARC _1ST_TIME" set is transmitted. The
value up to 20.0 (200) is transmitted.
○
PARC _2ND_TIME
"PARC _2ND_TIME" set is transmitted. The
value up to 20.0 (200) is transmitted.
○
PARC_ ENABLE_TIME
ENABLE set is transmitted.
The value up to 50000 is transmitted.
6-byte data is sent in total by 2 bytes each.
1ST_TIME, 2ND_TIME, and ENABLE_TIME
are sent from DC in that order.
0xB6
PULSE HARC
JUDGE TIME?
2byte
The judgment time for shifting into HAR ARC
processing is responded.
The value from 10(100us) to 6,500(65,000us)
is transmitted.
65,000us →
6,500
:
0x1964
0xB7
PULSE LINK
SET?
2byte
This sends back the predetermined
synchronization system number.
This sends back the parameters set in
PULS/LINK of the menu.
Number of systems:0
~
12(0x00
~
0x0C)
System No.:0
~
12(0x00
~
0x0C)
These values are sent.
Data is transmitted in the order of the number
of systems and the system No.
0xB8
PULSE HARC
JUDGE
COUNT?
1byte
The judgment frequency of ARC between
pulses for shifting into HAR ARC processing
is responded.
The value from 2 to 5 is transmitted.
5
:
0x05
0xB9
PULSE HARC
SHUTDOWN
TIME?
2byte
The shutdown processing time of HARD ARC
is responded.
The value from 0.1(1)to 50.0(500)is
transmitted.
500
:
0x01F4