DC Puse Power Supply
【
DC-10-4P
】
8
APPENDIX
85
Command
Transmission data
Acknowledgment data
Command
Command name
Capacity
Data content
Capacity
Data content
0x91
LEVEL?
2byte
This sends back the output command value.
The value to be sent back depends on the
number of units to connect and the current
output mode.
The current output mode can be confirmed by
the command 0x96.
Power: 0 to 6000 (60 kW: with the maximum 6
units connected (10 kW × 6))
Voltage: 0
~
800(800V)
Current: 0 to 1500 (150A: with the maximum 6
units connected (25A × 6))
0x92
POWER
?
2byte
The power value outputting is responded.
The value depends on the number of units to
connect.
0 to 600 (60 kW: with the maximum 6 units
connected (10 kW × 6))
0x93
VOLT?
2byte
The electric voltage value outputting is
responded.
0
~
1500(1500V)
0x94
CURRENT
?
2byte
The current value outputted is responded.
The value depends on the number of units to
connect.
0 to 1500 (150A: with the maximum 6 units
connected (25A × 6))
0x95
CONTROL
MODE?
1byte
The operation mode set is responded.
0x00 Local (LCL)
0x01 Serial
(
HST
)
0x02 User
(
USR)
0x96
OUTPUT MODE?
1byte
The output control mode set is responded.
Power
:
0x00
Voltage
:
0x01
Current
:
0x02
0x97
IGNITION
VOLTAGE
LIMIT?
2byte
The ignition voltage of the power supply set is
responded.
800
~
1500V
1500
:
0x05DC
0x98
PVIS MONITOR
?
7byte
The status values for each electric power,
electric voltage, electric current, and power
supply unit are collectively replied.
The data similar as:
Electric power for command 0x92;
Electric voltage for command 0x93;
Electric Current for command 0x94; and
Status for command 0x90, are collectively
replied.
The data of seven bytes in total is replied.
The reply is made in two bytes each for the
electric power, electric voltage, and electric
current.
The data from the electric power, electric
voltage, electric current, and status in this order
is transmitted.