DC Pulse Power Supply
【
DC-10-4P
】
2
OVERVIEW
11
2-5. Connection of input/output section
2-5-1. Connection of input/output section
Input voltage: Three-phase, 50/60 Hz, and AC342 to 440V
[HARTING] connector is employed for the input section.
Although the genuine cable can be purchased from us, if you prepare a cable by yourself, purchase
connector component parts with reference to the items of [Table 2-5.HARTING connector configuration
at the cable side of input section], select a suitable wiring material, and complete the installation.
special tool is required. Contact the manufacturer for the details of installation conditions etc. When
selecting a wiring material used for the cable, refer to [Table 2-1. Electrical specification], and select
the one that would satisfy the rating specification. In addition, select a suitable cable ground based on
the line shape of the wiring material selected.
Figure 2-2. Assignment of input connector at the product side
Table 2-5. HARTING connector configuration at the cable side of input section (Crimp TYPE)
Name
Model
Q’ty
70A crimp module,female
09 14 002 3141
2
Hinged frame 6B
(
A-B
)
09 14 006 0361
1
Hood Top Entry PG29
09 30 006 0443
1
Locking element
09 14 000 9960
1
70A contact female 16mm
2
09 11 000 6232
4
Table 2-6. HARTING connector configuration at the cable side of input section (Axial TYPE)
Name
Model
Q’ty
70A axial module female 10-22mm
2
09 14 002 2742
2
Hinged frame 6B
(
A-B
)
09 14 006 0361
1
Hood Top Entry PG29
09 30 006 0443
1
Locking element
09 14 000 9960
1
Table 2-7. HARTING connector pin assignment at the cable side of input section
Connector Pin Number
Connection destination
A
L1(R phase)
B
L2(S phase)
C
L3(T phase)
frame
GND