DC Pulse Power Supply
【
DC-10-4P
】
4
DESCRIPTION OF FUNCTIONS
38
・
Ramp start
The ramp start value can be set in [%] of the set value.
As usual, the lamp rises up to the value specified at the lamp start, and thereafter, rises up to the
command value following to the lamp time.
ランプタイム
0V
0A
t
指令値
指令値
ランプ
スタート
ランプ
スタート
Figure 4-12: Waveform at the ramp.
* If the ramp time function is enabled, the value will not be changed even changing the instruction
value while the output is on.
The instruction value when turned ON becomes the ramp reaching output.
Ramp start
Command value
Command value
Ramp start
Ramp time