HOW TO OPERATE
43
5. HOW TO OPERATE
This section describes how to operate and handle this power supply.
5-1. How to operate in LOCAL mode
This section describes the power operation in the LOCAL mode.
In the LOCAL mode, set ON/OFF of the DC output and various parameters on the front panel of the
power supply.
5-1-1. At Power-on
At startup, the model appears in the display.
Ex.
:
DC-10-P
After the model appears, it automatically switches to the main screen.
Use the main screen above as an example.
Press the ENT button when making changes to the settings to display.
Move to the setting item to be changed and press the ENT button to accept the changes.
PSET
:
The display shows the output control mode
PSET
:
Select when using in the power control.
VSET
:
Select when using in the voltage control.
ISET
:
Select when using in the current control.
0.0kW
:
The current output command value is displayed. The command value can be changed on
the front section only in the LOCAL mode.
The display of units following values automatically changes depending on the current control
mode.
kW: at PSET,
V: at VSET,
A: at ISET
LCL
:
The display shows the operation mode
LCL
:
Select when using in the LOCAL mode.
HST
:
Select when using in the HOST mode.
USR
:
Select when using in the USER mode.
CONT
:
The display shows the oscillation mode.
CONT
:
Select when using in the continuous mode.
1PLS
:
Select when using in the one pulse mode.
DCMD
:
Select when using in the DC mode.