DC Pulse Power Supply
【
DC-10-4P
】
5
HOW TO OPERATE
58
Table 5-3: Output parameter (limit value, ignition voltage, timer, etc.)
No
Description
Hierarchically
Setting rage
Variable
width
Unit
Initial value
1
Setup of the limit value of
the output power.
CNFG/LIMT/POWR
0
~
(α×10)
0.1
kW
Rated
value*1
2
Setup of the limit value of
the output voltage.
*2
CNFG/LIMT/VOLT
Oscillation frequency
10kHz
~
150kHz
:
0
~
800
Oscillation frequency
155kHz
~
250kHz
:
0
~
650
1
V
800
650
3
Setup of the limit value of
the output current.
CNFG/LIMT/CRNT
0
~
(α×25)
0.1
A
Rated
value*
3
4
Setup of ignition voltage
CNFG/OTHR/IG V
800
~
1500
1
V
1500
5
Setup of set point light up
range
CNFG/OTHR/SETP
2
~
8
1
%
2
6
Setup of using/non-using
of the ramp
FUNC/RAMP/MODE
DISBL/ENABL
―
―
DISBL
7
Setup of the rise time from
the start of ramping to the
command value
FUNC/RAMP/TIME
0.05
~
600
0.01
s
0.05
8
Setup of the initial value
for the start of ramping
FUNC/RAMP/STRT
0
~
100
1
%
0
9
Setting
of
oscillation
frequency
Main screen
5kHz
~
150kHz
155kHz
~
250kHz
1
5
kHz
100
10
Reverse pulse width
Main screen
0.4us
~
5us
※
2
0.1
us
4.0
11
With/without using
compulsion oscillation
function
PULS/FORC
DISBL/ENABL
―
―
DISBL
*1, 3: It depends on the power configuration.
Example: Two units of DC-10-4P = 20kW structure
*1 (2×10)=20kW
*3 (2×25)=50A
*2 Depending on the oscillating frequency currently specified, the limit value changes automatically.