DC Pulse Power Supply
【
DC-10-4P
】
4
DESCRIPTION OF FUNCTIONS
37
4-10. Description of HARD ARC function
A HARD ARC function is equipped that performs a shutdown operation longer than the inter-pulse
ARC shutdown operation in a case unable to eliminate an ARC even performing an inter-pulse ACR
processing.
*In the HARD ARC function, the shutdown time and the condition for shifting into HARD ARC can be changed.
Following shows the shifting condition into HARD ARC.
Shifting into the HARD ARC if the inter-pulse ARC is occurred for n-times within the specified time
interval.
0V
0A
t 時間
電圧
電流
ARC
occurred
Hard ARC
interruption time
ARC
occurred
ARC
occurred
ARC
occurred
判定時間
判定時間
Figure 4-10: Image of HARC ARC waveform
4-11. Description of Ramp time function
4-11-1. Ramp time function
①
Setting the ramp time function
①
allows you to adjust the time necessary to reach the command
value, the ramp start value, etc.
・
Ramp time
The time necessary to reach the command value can be set. It starts within the set time.
* The ramp starts working after determining the ignition. Only for the constant voltage control, the lamp starts
working from the output start.
0V
0A
t
指令値
指令値
ランプタイム
0V
0A
t
指令値
指令値
No ramp time
With ramp time
Figure 4-11: Image of waveform at the ramp.
Voltage
Current
Time: t
Check time
Command value
Command value
Command value
Command value
Ramp time
Check time