DC Pulse Power Supply
【
DC-10-4P
】
5
HOW TO OPERATE
48
5-1-4. About MENU screen
・
Press the MENU button to display the menu screen.
The current hierarchy is displayed in the first line and the selected items in the second line.
CNFG: this is used to change various parameters.
MONI: this enables one to check the number of times that HARD ARCS are detected, and the
occurrence log of warnings and errors.
FUNC: this is for using and setting the ramp function and the timer.
PULS: Pulse synchronization and compulsive oscillation can be set.
Pressing the ◄
or ► button and select an item.
The currently selected item blinks. Pressing the ENT button accepts the item.
CNFG
:
this is used to set various parameters.
SYTM: this is used to set the operation mode and the number of connected power supplies
* They cannot be changed in the DC ON mode.
LIMT: this is used to decide the limits of each output value.
ARC: this enables one to change the process parameters used when an ARC occurs.
* At this level, the currently selected ARC parameter is displayed at the upper right.
OTHR: this enables one to set the ignition level and various options.
SYTM: The operation mode, output control mode, and the number of connected power supply
units can be specified.
*They cannot be changed in the DC ON mode.
CONT :this is used to select an operation mode.
MODE :this is used to select a output control mode.
UNIT
:this is used to select the number of power supplies in use.
The setup is carried out in the M/S.
* This setting is available only to the master device.
CONT
:
this is used to select an operation mode
LOCAL: Select this for operation using the front panel.
USER: Select this for operation via USER IO PORT.
HOST: Select this for operation via RS232C/RS485.
HOST+: This setting is selected when carrying out an operation by RS-232C/RS-485 and
using the USER I/O port only for the output.