DC Puse Power Supply
【
DC-10-4P
】
8
APPENDIX
86
Command
Transmission data
Acknowledgment data
Command
Command name
Capacity
Data content
Capacity
Data content
0x9C
RAMP ENABLE
?
1byte
This sends back the status whether the Ramp
operating function is ON or OFF.
0x00 : DISABLE
0x01 : ENABLE
0x9D
RAMP TIME?
2byte
The Ramp standup time set is responded.
600.00sec →60000
Transmitting in integer of 16 bits.
0x9E
RAMP TIME
START LEVEL?
1byte
The start value (level) for starting operation is
responded.
0
~
100%
0xA0
POWER LIMIT?
2byte
The output power limit of the power supply
set is responded.
0
~
60.0kW →600
600
:
0x0258
0xA1
VOLTAGE LIMIT?
2byte
The output voltage limit of the power supply
set is responded.
0
~
800V
800
:
0x0320
0xA2
CURRENT LIMIT?
2byte
The output current limit of the power supply
set is responded.
0
~
150.0A →1
500
1500
:
0x05DC
0xA4
PULSE
PARAMETER
SELECT?
1byte
A or B is responded for the SET value of the
ARC set.
For arc parameters that can issue a request
by the following 0xA5 to 0xAE, it is the A
value if the SET value set in DC is set to A or
the B value if it is set to B.
0x00 = SET_A
0x01 = SET_B
0xA5
DCMD ARC
SHUTDOWN
TIME?
1byte
The ARC shutdown time in DC mode is
responded. Shutdown time is a fixed value
and shown as follows.
0x01=1000us
0x0C=20000us
0x02=2000us
0x0D=25000us
0x03=3000us
0x0E=300000us
0x04=4000us
0x0F=35000us
0x05=5000us
0x10=400000us
0x06=6000us
0x11=45000us
0x07=7000us
0x12=50000us
0x08=8000us
0x09=9000us
0x0A=10000us
0x0B=15000us