DC Pulse Power Supply
【
DC-10-4P
】
3
PREPARATION
16
3-3. Wiring and connecting
Never connect cables under an energized state. For attaching or
removing the cables, do not forget to turn off the upper breakers to
secure safety by the lockout or tagout. Before removing the cables etc.,
wait for five minutes or more in order to avoid the danger of residual
electric voltage.
3-3-1. Cables connected to DC-10-4P
The use of DC power needs an input and output cables separately.
・
Input cable: three-phase + GND with a withstand voltage of 600V or more and a withstand
current of 50A or more.
・
Output cable: a High-frequency coaxial cable with a withstand voltage of 2,000V or more and a
withstand current of 30A or more.
These are available as our optional products. Indemnity 6.8 may be applied if the cables are
prepared by the customer. We recommend you to use our optional supplies.
For our optional products, refer to [Table 3-1. Processing of optional input cable terminal] and [Table
3-2. Processing of optional output cable terminal].
Table 3-1. Processing for optional input cable terminal
Connection
destination
Our cable color and load terminal
processing
Size of solderless
terminal
L1(R phase)
Black 1 (red insulation cap)
Φ10
L2(S phase)
Black 2 (white insulation cap)
Φ10
L3(T phase)
Black 3 (black insulation cap)
Φ10
GND
G/Y (green insulation cap)
Φ10
Table 3-2. Processing for optional output cable terminal
Connection
destination
Our cable color and load terminal
processing
Size of solderless
terminal
Cathode
Milky white (black insulation cap)
φ6
Anode
White (white insulation cap)
φ6
3-3-2. USER IO PORT process cable
For operation in the USER mode for the power supply, prepare cables for processing to USER
I/O PORT. In consideration of noise, we recommend installing the shortest wiring with
shielded electric wires.
In addition, operation other than in the USER mode needs the interlock pin (37-34 pin)
jumpered. For details on I/O, see 4-2-2-1 (table 4-5).