DC Puse Power Supply
【
DC-10-4P
】
8
APPENDIX
87
Command
Transmission data
Acknowledgment data
Command
Command name
Capacity
Data content
Capacity
Data content
0xAB
ARC SHUTDOWN
VOLTAGE?
2byte
The ARC detection voltage level set is
responded.
40
~
500V
500
:
0x01F4
0xAC
ARC SHUTDOWN
CURRENT?
1byte
The ARC detection current level set is
responded.
0
~
90A
90
:
0x5A
0xAD
HARD ARC
COUNT?
4byte
This sends back the number of accumulated
HARC occurrences.
The maximum number of counts is
99,999,999 times.
99,999,999 =
05F5E0FF
0xAE
PULSE ARC
COUNT?
4byte
The accumulated ARC generation frequency
between pulses is responded. The maximum
count number is 99,999,999.
99,999,999 =
05F5E0FF
0xB0
PULS MODE?
1byte
The specified oscillating frequency is replied.
Continuous mode
:
0x00
One pulse mode
:
0x01
DC mode
:
0x02
0xB1
PULS
OSC?
1byte
This sends back the synchronization settings
No synchronization (CINT)
:
0x00
System with synchronization 1(CMST)
:
0x01
System with synchronization (CSLV)
:
0x02
0xB2
PULS CYCLE?
2byte
The specified oscillating frequency is replied.
The set frequencies are sent as values from 5
to 250.
5
~
250kHz
250
:
0x00FA
0xB3
PULS WIDTH
2byte
The specified inversion pulse width is replied.
The set inversion pulse width is sent as
values from 4 to 50.
0.4
~
5.0us
5.0us
:
50
:
0x0032