DC Pulse Power Supply
【
DC-10-4P
】
4
DESCRIPTION OF FUNCTIONS
39
4-11-2. Ramp time function
②
By setting the r
amp time function
②
, only the time to reach the command value can be adjus
ted.Unlike the ramp time function
①
, it accepts changes in the command value while the output is
ON.
Ramp time
0V
0A
t
Command
value
Ramp
start
Command
value
Ramp
start
Ramp time
0V
0A
t
Command
value
Command
value
Ramp time function
①
Ramp time function
②
(Ramp time + Ramp start)
(Ramp time only)
Ramp time
0V
0A
t
Command
value
Command
value
LEVEL
0V
10V
Do not accept changes to
command values
Ramp time
0V
0A
t
Reached
value
Reached
value
LEVEL
0V
10V
Accept changes to command
values
Ramp time function
①
Ramp time function
②
(command value cannot be changed)
(command value can be changed)
Figure 4-13
:
Difference between Ramp time functions
①
and
②
Ramp time functions 1 and 2 cannot be used together.
If one ramp function is enabled, the other ramp function will be disabled.
CAUTION