DC Pulse Power Supply
【
DC-10-4P
】
3
PREPARATION
19
3-4-5. About pulse synchronization system
The reverse-pulses of multiple systems can be synchronized by using pulse synchronization
optical cables. To achieve the synchronization, you are required to connect the pulse
synchronization optical cable and set up the power supply unit.
Figure 3-7: Enlarged view of EXTPLS connector part on back of power supply
For the cable connection configuration, see below.
Using optical synchronization cables for connection, the EXTPLS connectors on the back of power
suplly can be daisy-chained from the first system. Up to 12 systems can be synchronized.
Connection example
: System 1 EXTPLS OUT -> System 2 EXTPLS IN -> System 2 EXT
PLS OUT -> .... -> System 12 EXTPLS IN
System 1
System 2
・・・・・・・・・・・・・・・・・・・・
System 12
Figure 3-8: How to connect optical cables
As Fig. 3-8, connect the optical synchronization cable from the "OUT" of
the upper power supply to the "IN" of the lower power supply in this order.
Transmission
side
Receiving
side
CAUTION
OUT
IN OUT
IN
Optical
synchronization
cable