DC Pulse Power Supply
【
DC-10-4P
】
4
DESCRIPTION OF FUNCTIONS
42
4-14. Screen lock function
The screen can be locked in order to avoid switching from the Start screen even pressing the button on
the front face.
If you would like to lock or release, contact the store of purchase.
If the buttons are used in the screen lock mode, "LOCK" appears at the upper right of the screen and
the screen cannot be switched.
4-15. About SETPOINT
If the DC output value is within ±2% of the set value in its initial state, the front SETPOINT LED lights
up and the SETPOINT signal becomes active.
The SETPOINT judgment criterion value is ±2% in the initial state, but can be changed between ±2%
and ±8%.
Change the value depending on your circumstances.
If the compulsive oscillation mechanism is enabled, in some cases, the SETPOINT may be turned on
before starting the discharge.
How to set the compulsive oscillation, refer to 5-1-4. MENU screen.
4-16. About RESET
Do not fail to apply a RESET signal only when an ERROR is generated (FAIL status).
Note that if the RESET signal is applied while the output is underway, the output may be drooped for a
certain period.