DC Pulse Power Supply
【
DC-10-4P
】
2
OVERVIEW
12
2-5-2. Connection of output section
As with the input section, a [HARTING] connector is employed also in the output section.
Although the genuine cable can be purchased from us, if you prepare a cable by yourself, purchase
connector component parts with reference to the items of [Table 2-8. HARTING connector
configuration at the cable side of output section], select a suitable wiring material, and complete the
installation.
A special tool is required. Contact the manufacturer for the details of installation conditions etc.
When selecting a wiring material used for the cable, refer to [Table 2-1. Electrical specification], and
select the one that would satisfy the rating specification.
In addition, select a suitable cable ground based on the line shape of the wiring material selected.
Figure 2-3. Assignment of output connector at the product side
Table 2-8. HARTING connector configuration at the cable side of output section
Name
Model
Q’ty
Han 70A crimp module,male
09 14 002 3041
1
Carrier hood
09 14 001 0311
1
Hood Top Entry M25
72 14 001 0401
1
70A contact,male 6mm
2
09 11 000 6130
1
70A contact,male 4mm
2
09 11 000 6137
1
Table 2-9. HARTING connector pin assignment at the cable side of output section
Connector Pin Number
Connection destination
1
Cathode
2
Anode
It is recommended to use our cable for input/output cables.
We shall not take any responsibility on malfunctions and defects as a result of
using a cable which is prepared by the customers. Please acknowledge
beforehand.
CAUTION
Содержание DC-10-4P